site stats

Cttsbd

WebThe CTTSBD utility searches the data set group definitions for a WITHGRP statement that indicates that the current data set must be stacked together with the data sets on the candidate volume chain. An appropriate WITHGRP statement can exist in the data set group definition of the current data set and/or a data set on the candidate volume chain. WebThe CTTSBD utility uses media definitions specified during Control-M/Tape installation (and other information) during calculation of output volume capacity. If volume capacity information produced during a run of CTTSBD appears to be inaccurate, it may be necessary to modify the media definition for the relevant volumes.

Messages CTTB00 through CTTBxx

WebCTTSBD disk processing includes sequential processing of the Media database and multiple sort phases. In NORMAL mode, disk processing is performed during the selection phase only. After the first volume is mounted for copying, disk processing becomes minimal. In SIMULATION mode, volume selection is the primary action performed by the utility. WebCTTSBD Example 4. This example performs a run of the CTTSBD utility in simulation mode. In this run, copying of all the site’s data sets from 3490 cartridges to 3590 cartridges is simulated. New names are assigned to the output data sets. Data set groups are determined according to first letter of each input data set name. porter nissan service hours https://daisyscentscandles.com

IEA705I ERROR DURING GETMAIN SYS CODE = 878-10

WebFeb 14, 2024 · IEA995I SYMPTOM DUMP OUTPUT 800. SYSTEM COMPLETION CODE=878 REASON CODE=00000010. TIME=17.40.57 SEQ=05583 CPU=4000 … WebThe CTTSBD utility augments the Control-M/Tape Dynamic Dataset Stacking facility by allowing multiple pre-existing data sets to be copied and stacked according to specified criteria. Data sets are placed on output volumes according to stacking parameters and runtime parameters specified by the user. WebThe following steps must be performed before the first run of the CTTSBD utility at your site: Allocate and format the CTTSBD utility Checkpoint-Restart data set using the CTTSBF batch job in the Control-M/Tape JCL library. Implement security considerations. The CTTSB Control-M/Tape utility reads and writes data sets in the library for your site. porter nsha

Retention

Category:Retention

Tags:Cttsbd

Cttsbd

Relevant Installation Parameters

WebBMC recommends that you run the CTTRTM utility after running the CTTSBD utility to scratch newly freed volumes. Note: If data sets with CYCLE type retention are to be handled by the CTTSBD utility, a specific number must be specified for the INRET and OUTRET utility parameters. If a data set with CYCLE type retention is detected and no specific ... WebCTTSBD utility enters endless loop: PDF: Technical Bulletin 31-Mar-2024 (ID 295335) Technical bulletin: Scheduled outage for filedownload.bmc.com and SMP/E RECEIVE ORDER services and changes to file server: HTM: 15-Nov-2024: Alerts INCONTROL customers to necessary 2024 year-end procedures. PDF: 17-Dec-2024

Cttsbd

Did you know?

WebThe CTTSBD utility can be run in simulation mode. This mode can be used to experiment with various stacking configurations (meaning, data set group definitions) without effecting data set location in the tape library. In simulation mode, the CTTSBD utility calculates output volume capacity according to the value specified for the OUTVOLMB ... WebFeb 27, 2015 · Например, в популярной ролевой игре Skyrim TBD не имеет ничего общего с датой выхода игры или дополнения. Так сокращается игровая раса, …

WebMask characters are supported for many of the parameters of the CTTSBD utility. The ability to use mask characters is indicated in the description of the relevant parameters. The following mask characters can be used: Table 369 CTTSBD Masks. Mask. Description? Represents any one character * WebCTTSBD utility enters endless loop: PDF: Technical Bulletin 09-Nov-2024: Alerts all INCONTROL customers to necessary 2024 year-end procedures. PDF: 03-Nov-2024: Alerts all INCONTROL customers to necessary 2024 year-end procedures. PDF: 24-Nov-2024: BMC is announcing a new method for sending files to Customer Support. PDF: 03-Nov …

WebApr 7, 2024 · NEVER cancel a running CTTSBD, you may corrupt the MDB and it will take time to repair it. 2. There is a Modify command to stop CTTSBD at the next logical "event" if necessary: F cttsbd,STOP (documented in the Utility Guide) 3. There is a SIMULATION mode to check which files have been selected, but this mode will not provide a pertinent … WebSep 15, 2024 · CTTSBD. Performs data set stacking in batch mode. CTTSCA. Detects data set contentions. CTTSTK. Builds and updates the Stacking Database. CTTSTKR. …

WebAug 20, 2006 · Posted: Fri Sep 01, 2006 8:51 pm. Reason : Specification exception. Usually caused by incorrect boundary. Read the description for pausible causes. Description : …

WebCTTSBD utility enters endless loop: PDF: Technical Bulletin 15-Nov-2024: Alerts INCONTROL customers to necessary 2024 year-end procedures. PDF: 24-Feb-2024: BMC is notifying users of an extension of the period of full support for Control-M versions 9.0.19 and 9.0.20. PDF: 17-Dec-2024 porter new homesWeb(These data sets may have been created by a previous run of the CTTSBD utility.) No prefix is added to output data set names for group NEW. The CTTSBD utility selects all data sets from group ACCT and group NEW. The following output data sets are created by this run of the CTTSBD utility: Table 368 CTTSBD Data Sets only svg fileWebSep 15, 2024 · The CTTSBD utility copies data sets residing on removable media. It supplements the Control-M/Tape Dynamic Dataset Stacking facility, which controls the placement of data sets at time of creation. The CTTSBD utility enables you to copy existing data sets (input data sets) from one location to another. Output data sets (the new … on what day is texas independence dayWebHas anyone had experience with CTTSBD utility of CONTROL-M/T to copy volumes (not stacking just copy one to one) and willing to share his/her experience? Thanks, Arye Shemer-----For IBM-MAIN subscribe / signoff / archive access instructions, send email to ***@bama.ua.edu with the message: GET IBM-MAIN INFO ... porter o\u0027grady lawyers pty ltdWebOUTUNIT – Unit name to be used by the CTTSBD utility for allocation of each output data set in this group. A name of up to eight characters can be specified. If a value is specified for OUTUNIT in the group definition, that value overrides the OUTUNIT name specified in the TYPERUN statement of the CTTSBD utility. DATASET only the brave sub indoWebCTTSBD utility enters endless loop: PDF: Technical Bulletin 09-Nov-2024: Alerts all INCONTROL customers to necessary 2024 year-end procedures. PDF: 03-Nov-2024: Alerts all INCONTROL customers to necessary 2024 year-end procedures. PDF: 24-Nov-2024: BMC is announcing a new method for sending files to Customer Support. PDF: porter o grady shared governanceporter official site